THE EFFECT OF HYDROXYAPATITE LAYER ON BIOACTIVITY AND CORROSION RATE OF TITANIUM-12CR IN SIMULATED BODY FLUID

Irfan, Idris (2021) THE EFFECT OF HYDROXYAPATITE LAYER ON BIOACTIVITY AND CORROSION RATE OF TITANIUM-12CR IN SIMULATED BODY FLUID. Diploma thesis, Universitas Andalas.

This is the latest version of this item.

[img] Text (Cover and Abstrak)
Cover and Abstrak.pdf - Published Version

Download (135kB)
[img] Text (Bab 1 Pendahuluan)
BAB 1.pdf - Published Version

Download (136kB)
[img] Text (Bab 5 Penutup)
BAB 5.pdf - Published Version

Download (53kB)
[img] Text (Daftar Pustaka)
Daftar Pustaka.pdf - Published Version

Download (105kB)
[img] Text (Skripsi Full Text)
Tugas Akhir Irfan Idris.pdf - Updated Version
Restricted to Repository staff only

Download (2MB)

Abstract

Biomaterial implant is an orthopedic treatment to treat fracture problems. The popular material used in this case is titanium. Pure titanium and its alloys have better biocompatibility and biomechanical properties than other metals, while stainless steel and cobalt chromium have lower biocompatibility and corrosion resistance than titanium. In addition, this stainless steel and cobalt chromium have a higher modulus of elasticity that will lead to a pain and bruising in the joints. Titanium type ᵦ or Ti-12Cr is interested to develop for biomedical application because that kind of alloy has an excellent biocompatibility and mechanical properties which it can be controlled. Titanium is not perfect, there is some problem in titanium such as less bioactive to induce precipitation of Calcium phosphate (CaP), it can reduce bone osseointegration with implant material. Therefore, it is necessary to do a coating treatment on the material. In this study, the coating process on Ti-12Cr material was carried out. The coating was carried out using hydroxyapatite with the Electrophoretic Deposition method and sintered at a temperature of 700ºC. After that, an in vitro test was carried out, by immersing the material in a Simulated Body Fluid solution using an incubator shaker at a temperature of 36.5°C. This test uses time variations, namely 1 week, 2 weeks, 3 weeks and 4 weeks. After soaking, the surface of the material was examined using a macro microscope and SEM. After that, the weight loss method was used to determine the corrosion rate by comparing the weight of the material at the beginning before immersion and after immersion. The test results with SEM observations showed the presence of apatite growth in the second week to the fourth week on the surface of the hydroxyapatite-coated material. The growth is in the form of tapered hydroxyapatite cells which will continue to increase along with the immersion of the material. In the uncoated material there are several cavities which indicate that corrosion has occurred. With the weight loss method, the corrosion rate of the uncoated material is much higher than the corrosion rate of the coated material.

Item Type: Thesis (Diploma)
Primary Supervisor: Dr. Eng. Ilhamdi
Uncontrolled Keywords: implant biomaterial, Titanium-12 Chromium (Ti-12Cr), in vitro test, Simulated Body Fluid, microstructure, corrosion rate
Subjects: R Medicine > RD Surgery
R Medicine > RJ Pediatrics
R Medicine > RK Dentistry
T Technology > TJ Mechanical engineering and machinery
T Technology > TS Manufactures
Divisions: Fakultas Teknik > Mesin
Depositing User: s1 teknik mesin
Date Deposited: 26 Aug 2021 03:12
Last Modified: 26 Aug 2021 03:12
URI: http://scholar.unand.ac.id/id/eprint/80757

Available Versions of this Item

Actions (login required)

View Item View Item