Masayu, Rannie Safitri (2019) Determination of Tuned Liquid Column Damper Frequency and Damping Ratio Using Pendulum Vibration System. Diploma thesis, Universitas Andalas.
|
Text (Cover dan Abstrak)
1. Cover dan Abstrak.pdf - Published Version Download (114kB) | Preview |
|
|
Text (BAB 1)
2. BAB 1.pdf - Published Version Download (116kB) | Preview |
|
|
Text (BAB 5)
3. BAB 5.pdf - Published Version Download (33kB) | Preview |
|
|
Text (Daftar Pustaka)
4. Daftar Pustaka.pdf - Published Version Download (146kB) | Preview |
|
Text (Tugas Akhir Ilmiah Utuh)
5. Tugas Akhir Ilmiah Utuh.pdf - Published Version Restricted to Repository staff only Download (3MB) |
Abstract
Nowadays, one of the most popular dynamic vibration absorbers is TLCD (Tuned Liquid Column Damper). TLCD is a passive vibration control system that doesn’t need external energy to suppress the vibration response. TLCD can absorb the vibration of the structure by transferring the energy of vibration to the movement of liquid inside TLCD. TLCD can simply use for any type of structural design and its application doesn’t need to change the existing structural design. To use this absorber, some parameter, such as natural frequency and damping ratio of TLCD must be determined. This research is conducted to determine TLCD natural frequency and damping ratio using pendulum vibration system. Simulation study and experimental testing are performed to determine TLCD parameters. From known natural frequency of the dynamic pendulum with TLCD system, natural frequency and damping ratio of TLCD can be predicted and those parameters can be proved by simulation study. For a dynamic pendulum system that has the natural frequency between 1.47 Hz and 2.03 Hz, parameters of TLCD obtained are 10.743 rad/s for natural frequency and 0.05 for damping ratio. The simulation result shows that the TLCD predicted parameters from natural frequency of dynamic system and simulation parameters of TLCD is approaching. It proves that the natural frequency and damping ratio of TLCD can be determined from natural frequency of the pendulum system.
Item Type: | Thesis (Diploma) |
---|---|
Primary Supervisor: | Dr.Eng. Lovely Son |
Uncontrolled Keywords: | TLCD, simulation testing, natural frequency, damping ratio. |
Subjects: | T Technology > TJ Mechanical engineering and machinery |
Divisions: | Fakultas Teknik > Mesin |
Depositing User: | s1 teknik mesin |
Date Deposited: | 24 Oct 2019 15:28 |
Last Modified: | 24 Oct 2019 15:28 |