Nanang, Sumitra (2019) ANALISIS KURVA PERCENTAGE DEPTH DOSE (PDD) DAN PROFILE DOSE UNTUK LAPANGAN RADIASI ELEKTRON PADA PESAWAT LINAC TIPE CLINAC-CX DI RS UNAND. Diploma thesis, Universitas Andalas.
|
Text (Cover dan Abstrak)
cover dan abstrak.pdf - Published Version Download (108kB) | Preview |
|
|
Text (BAB I (Pendahuluan))
BAB I (Pendahuluan).pdf - Published Version Download (106kB) | Preview |
|
|
Text (BAB Akhir ( Kesimpulan dan Saran))
BAB Akhir (Kesimpulan dan Saran).pdf - Published Version Download (114kB) | Preview |
|
|
Text (Daftar Pustaka)
Daftar Pustaka.pdf - Published Version Download (123kB) | Preview |
|
Text (Tugas Akhir Ilmiah Utuh)
Tugas Akhir Ilmiah Utuh.pdf - Published Version Restricted to Repository staff only Download (2MB) |
Abstract
ANALISIS KURVA PERCENTAGE DEPTH DOSE (PDD) DAN PROFILE DOSE UNTUK LAPANGAN RADIASI ELEKTRON PADA PESAWAT LINAC TIPE CLINAC-CX DI RS UNAND ABSTRAK Telah dilakukan analisis terhadap kurva percentage depth dose (PDD) dan profile dose untuk lapangan radiasi elektron pada pesawat LINAC tipe Clinac-CX. Pada penelitian ini digunakan energi berkas elektron 9, 12, 15 dan 18 MeV dengan lapangan radiasi no off-set, off-set 1 cm, dan off-set 3 cm. Hasil penelitian yang diperoleh menunjukkan bahwa semakin besar energi berkas elektron maka semakin besar pula kedalaman maksimum (Z_maks). Selain itu, pada pengukuran PDD diperoleh hasil ketidakakuratan yang bervariasi antara 1,03% - 13,1%. Ketidakakuratan terjadi pada energi 12 MeV pada posisi kedalaman ionisasi mencapai maksimum (R100), kedalaman ionisasi mencapai 50% (R50) sebesar 3,43%, 2,18%. Sementara itu pada energi 9 MeV dan 15 MeV ketidakakuratan terjadi pada posisi R50 dan R100 sebesar 3,01%, 13,1%. Ketidakakuratan diatas 2% yang tidak sesuai standar AAPM TG-40 tahun 1994. Pada pengukuran profile dose didapatkan nilai symmetry dan flatness pada tiap energi dan lapangan radiasi masih dalam batas toleransi yang ditetapkan oleh AAPM TG-40 yaitu 3%. Begitu juga dengan nilai penumbra yang diperoleh masih dalam batas toleransi yaitu 10-15 mm. Kata kunci : elektron, percentage depth dose, profile dose, LINAC. ANALYSIS OF PERCENTAGE DEPTH DOSE (PDD) CURVES AND DOSE PROFILE FOR ELECTRONIC RADIATION FIELDSIN LINAC TYPE CLINAC-CX IN UNAND HOSPITAL ABSTRACT An analysis of the percentage depth dose (PDD) curve and profile dose for the electron radiation field have been carried out on LINAC Clinac-CX type aircraft. In this study, electron beam energy 9, 12, 15 and 18 MeV were used with no off-set, off-set 1 cm and off-set 3 cm radiation fields. The results obtained show that the greater the electron beam energy, the greater the maximum depth (Zmaks). In addition, the PDD measurement results show that inaccuracies vary between 1.03% - 13.1%. Inaccuracies occur at 12 MeV energy at the position where the ionization depth reaches a maximum (R100), the ionization depth reaches 50% (R50) of 3.43%, 2.18%. Meanwhile, in the energy of 9 MeV and 15 MeV inaccuracies occur in the position of R50 and R100 of 3.01%, 13.1%. Inaccuracies above 2% that are not in accordance with the AAPM TG-40 standard of 1994. In the measurement of profile dose, the symmetry and flatness values for each energy and radiation field are still within the tolerance limits set by the AAPM TG-40 which is 3%. Likewise, the penumbra value obtained is still within the tolerance range of 10-15 mm. Keywords: electron, percentage depth dose, profile dose, LINAC.
Item Type: | Thesis (Diploma) |
---|---|
Primary Supervisor: | Dian Milvita M.SI |
Uncontrolled Keywords: | Kata kunci : elektron, percentage depth dose, profile dose, LINAC. |
Subjects: | Q Science > QC Physics |
Divisions: | Fakultas Matematika dan Ilmu Pengetahuan Alam > Fisika |
Depositing User: | s1 fisika fisika |
Date Deposited: | 18 Oct 2019 15:58 |
Last Modified: | 18 Oct 2019 15:58 |