Fuadi, Ramdani (2022) AUDIT ENERGI DAN ANALISIS PENGHEMATAN KONSUMSI ENERGI PADA SISTEM PENGKONDISIAN UDARA DI GEDUNG RUMAH SAKIT UNIVERSITAS ANDALAS. Diploma thesis, Universitas Andalas.
|
Text (Cover dan Abstrak)
Cover dan Abstrak.pdf - Published Version Download (235kB) | Preview |
|
|
Text (BAB I PENDAHULUAN)
BAB I PENDAHULUAN.pdf - Published Version Download (275kB) | Preview |
|
|
Text (BAB V SIMPULAN DAN SARAN)
BAB V SIMPULAN DAN SARAN.pdf - Published Version Download (211kB) | Preview |
|
|
Text (DAFTAR KEPUSTAKAAN)
DAFTAR KEPUSTAKAAN.pdf - Published Version Download (275kB) | Preview |
|
Text (TA Lengkap)
TA Lengkap_Fuadi Ramdani.pdf - Published Version Restricted to Repository staff only Download (2MB) |
Abstract
Based on Presidential Instruction No. 10 of 2005 concerning energy saving, it is necessary to carry out energy management so that the use of energy, especially electrical energy, becomes more efficient. This is in contrast to the condition of energy consumption at Andalas University Hospital, where the hospital complains of an increase in electricity bills every month. One of the possible causes for the swelling of electricity bills is the large consumption of air conditioning power. Therefore, an energy audit research was conducted on the air conditioning system at Andalas University Hospital. The purpose of this research is to obtain data on energy use and information on opportunities for saving electrical energy in the air conditioning system at Andalas University Hospital. This electrical energy saving is done by calculating the value of the energy consumption intensity (IKE) of the Andalas University Hospital and the IKE of the air conditioning system. Based on the calculation results, the IKE value of Andalas University Hospital is 108.68 kWh/m2/year and the IKE value of the air conditioning system is 69.03 kWh/m2/year. The IKE value obtained is classified as efficient, but to maximize electrical energy savings, the air conditioner operating hours are reduced by 2 hours each working day as well as periodic maintenance and repairs. So that the obtained electrical energy savings of 134,610.96 kWh/year.
Item Type: | Thesis (Diploma) |
---|---|
Primary Supervisor: | Muhammad Nasir Sonni, Ph.D |
Uncontrolled Keywords: | Energy Audit, IKE, Air Conditioning, Energy Saving, Electrical Energy |
Subjects: | T Technology > TA Engineering (General). Civil engineering (General) T Technology > TK Electrical engineering. Electronics Nuclear engineering |
Divisions: | Fakultas Teknik > Elektro |
Depositing User: | S1 Teknik Elektro |
Date Deposited: | 07 Mar 2022 04:49 |
Last Modified: | 07 Mar 2022 04:49 |
URI: | http://scholar.unand.ac.id/id/eprint/100163 |